List of Parameters
9-10
9.1.5 Class 4: I/O monitor setting
No.
Title
Unit
Range
Size
[byte]
Function/Contents
Attribute
Related
control
mode
Reference
00
SI1 input selection
-
-2147483648
to
2147483647
4
Set function and logic of SI1.
C
S
All
2.4.1
01
SI2 input selection
-
-2147483648
to
2147483647
4
Set function and logic of SI2.
C
S
All
2.4.1
02
SI3 input selection
-
-2147483648
to
2147483647
4
Set function and logic of SI3.
C
S
All
2.4.1
03
SI4 input selection
-
-2147483648
to
2147483647
4
Set function and logic of SI4.
C
S
All
2.4.1
04
SI5 input selection
-
-2147483648
to
2147483647
4
Set function and logic of SI5.
C
S
All
2.4.1
05
SI6 input selection
-
-2147483648
to
2147483647
4
Set function and logic of SI6.
C
S
All
2.4.1
06
SI7 input selection
-
-2147483648
to
2147483647
4
Set function and logic of SI7.
C
S
All
2.4.1
07
SI8 input selection
-
-2147483648
to
2147483647
4
Set function and logic of SI8.
C
S
All
2.4.1
10
SO1 output
selection
-
-2147483648
to
2147483647
4
Set SO1 function allocation.
C
S
All
2.4.2
11
SO2 output
selection
-
-2147483648
to
2147483647
4
Set SO2 function allocation.
C
S
All
2.4.2
12
For manufacturer’s
use
-
-
4
Permanently set at 0.
-
-
-
16
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
17
For manufacturer’s
use
-
-
4
Permanently set at 0.
-
-
-
18
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
19
For manufacturer’s
use
-
-
4
Permanently set at 0.
-
-
-
21
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
22
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
23
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
24
For manufacturer’s
use
-
-
2
Permanently set at 0.
-
-
-
31
Positioning
complete
(In-position) range
Comman
d unit
0 to 2097152
4
Set allowable the number of
pulses for positioning complete
signal (INP).
Unit is according to Pr5.20
“Position setup unit select”.
A
Position,
Full-closed
4.2.4
32
Positioning
complete
(In-position) output
setup
-
0 to 10
2
Set the condition for positioning
complete output.
A
Position,
Full-closed
4.2.4
(To be continued)