7.3Warning function
7-33
Class
No.
Attribute
(Note 1)
Title
Range
Unit
Function
6
96
A
Over-load warning
release level
0 to 114
%
Sets the threshold value for releasing the warning when
the load factor decreases from the state when the
overload warning is occurring.
Sets with the overload load factor.
If 0 is set, overload warning detection is performed under
conventional conditions (85% of overload protection
level).
In addition, if other than "Pr6.96 <= Pr6.95 < (Overload
protection level)" is set, overload warning detection is
performed under conventional conditions (85% of
overload protection level).
6
97
B
Function
expansion setup 3
-2147483648
to
2147483647
-
bit 1: Deterioration diagnosis warning function
0:Invalid
1:valid
7
14
C
Main power off
warning detection
time
0 to 2000
1 ms
Specifies a time to wait until a main power off warning is
detected when main power shut-off continues.:
0 to 9, 2000:
10 to 1999:
Warning detection is disabled.
Unit is [ms]
PSM
Pr.
Name
Setting
range
Shipping
setting
Unit
Content
03
Main power off warning
detection time
0 to 2000
40
ms
Sets the main power off warning detection time. The main
power off warning is not detected when the setting value is
smaller than 10 or is set to 2000.