EasyManua.ls Logo

Panasonic MINAS A6 Multi Series - Page 62

Panasonic MINAS A6 Multi Series
306 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Basic Functions
4-6
Electronic gear setting example
Under semi-closed control, When setting the electronic gear ratio of axis A by setting the number
of command pulses per motor revolution
608Fh-01h (Encoder increments) is set automatically from the connected encoder resolution.
By setting 608Fh-02h (Motor revolutions), 6091h-01h (Motor shaft revolutions), 6091h-02h (Driving shaft
revolutions) and 6092h-02h (Driving shaft revolutions) to 1 (shipment condition), it is possible to set
6092h-01h (Feed) as the "number of command pulses per motor revolution".
Under semi-closed control or full-closed control, When setting the electronic gear ratio of axis A by
setting the electronic gear numerator/denominator
608Fh-01h (Encoder increments) is set automatically from the connected encoder resolution.
By setting 6092h-01h (Feed) to the encoder resolution (the same value as 608F-01h (Encoder increments),
and in the case of the 23bit/r encoder, the shipment condition) and setting 608Fh-02h (Motor revolutions) and
6092h-02h (Driving shaft revolutions) to 1 (shipment condition), it is possible to set 6091h-01h (Motor shaft
revolutions) to the "electronic gear numerator" and 6091h-02h (Driving shaft revolutions) to the "electronic
gear denominator".
Backup of electronic gear set value
The electronic-gear-related objects (6091h/6891h-01h, 6091h/6891h-02h, 6092h/6892h-01h and
6092h/6892h-02h) are backup target objects.
It is recommended to execute a backup (writing into EEPROM) after a change.
By executing a backup, it will be unnecessary to change setting each time when the control power is turned
on.
As for the backup method, refer to "TECHNICAL REFERENCE EtherCAT Communication Specification
(SX-DSV03456)".