Chapter 7Appendix — Technical information
ENGLISH - 143
r Received data
Header Data section
Termination
symbol
Command
example
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
Data length
1 byte 1 byte Undened length 1 byte
r Error response
String Details
Termination
symbol
Message
“ERR1” Undened control command
(CR)
0x0d
“ERR2” Out of parameter range
“ERR3” Busy state or no-acceptable period
“ERR4” Timeout or no-acceptable period
“ERR5” Wrong data length
“ERRA” Password mismatch
Data length
4 bytes 1 byte
Control command
The following table lists the commands that can be used to control the projector using a computer.
r Projector control command/query command
Command Details
Parameter/response
string
Remark (parameter)
PON Power on
To check if the power is on, use the “Power supply status query”
command.
POF Power standby
QPW
Power supply status
query
000
001
STANDBY status
Power on status
IIS Input/mode selection
HD1 HDMI
MV1 MEMORY VIEWER
MC1 MIRRORING
PA1 Panasonic APPLICATION
SI1 SIGNAGE
OLP
Light source power
setting
0 NORMAL
QLP
Light source power
setting query
1 ECO
QST Runtime query 00000 - 99999 In hours
OSH AV mute 0 AV mute function off
QSH AV mute status query 1 AV mute function on
AUU Volume up
AUD Volume down

Table of Contents