Pay particular attention to faults that need to be fixed. Refer to Table 84 for
corrective action suggestions.
Error Codes
Table 84 contains a list of error messages and a brief description of
corrective action.
Error Code Resolution
EØ—Motor Configuration Warning The motor rating is too high for the drive, and the
drive is using its own limits for safety reasons.
E1—Motor Configuration Error One of the motor parameters is set to zero (Ø).
Look at the additional errors to find which parameters
are set at zero (Ø). Refer to your motor specifications
for the correct value.
E3—Max Inductance = Ø This parameter is set to zero (Ø). To correct the
error, you must set a non-zero (Ø) value. Refer to
your motor specifications for the correct value.
(DMTIND)
E4—Rated Speed = Ø This parameter is set to zero (Ø). To correct the
error, you must set a non-zero (Ø) value. Refer to
your motor specifications for the correct value.
(DMTW)
E5—DPOLE = Ø This parameter is set to zero (Ø). To correct the
error, you must set a non-zero (Ø) value. Refer to
your motor specifications for the correct value.
(DPOLE)
E6—Resistance = Ø This parameter is set to zero (Ø). To correct the
error, you must set a non-zero (Ø) value. Refer to
your motor specifications for the correct value.
(DMTRES)
E7—Ke = Ø This parameter is set to zero (Ø). To correct the
error, you must set a non-zero (Ø) value. Refer to
your motor specifications for the correct value.
(DMKE)
E8—Continuous Current = Ø This parameter is set to zero (Ø). To correct the
error, you must set a non-zero (Ø) value. Refer to
your motor specifications for the correct value.
(DMTIC)
E9—Peak Current = Ø This parameter is set to zero (Ø). To correct the
error, you must set a non-zero (Ø) value. Refer to
your motor specifications for the correct value.
(DMTIP)
E1Ø—Continuous Current Too High The continuous current of the motor is higher than
the continuous current rating of the drive. Use the
continuous current rating for the drive.
E11—Torque Rating Is Greater than
Peak Power Rating
The motor’s torque rating is too high for the power
level of the drive. Use the drive’s torque rating.
E12—Peak Current Too High The peak current of the motor is higher than the peak
current rating of the drive. Use the drive’s value for
peak current.
E13—Inertia = Ø This parameter is set to zero (Ø). The drive will not
enable Velocity or Position Modes. To correct the
error, you must set to a non-zero value. Refer to your
motor specifications for the correct value. (DMTJ)
E14—Damping = Ø This parameter is set to zero (Ø). The drive will not
enable Velocity or Position Modes. To correct the
188 ACR9000 Series Hardware Installation Guide
www.comoso.com

Table of Contents

Other manuals for Parker ACR Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker ACR Series and is the answer not in the manual?

Parker ACR Series Specifications

General IconGeneral
BrandParker
ModelACR Series
CategoryController
LanguageEnglish

Related product manuals