K3.1.141e Manual NitroFlow HP_EN.doc - 16 -
4 Technical specifications
4.1 General
Delivery pressure
Max. delivery pressure (vessel) inlet pressure minus pressure drop (max. 2
bar(g) / 29 psig)
Ambient conditions
Temperature 10°C to 40°C / 50°F to 104°F
Air quality Normal clean ambient air, relative humidity <
90%
Pressurized air specifications
Max feed pressure 13 bar(g) / 190 psig
Compressed air temperature range 10-50°C / 50-120°F
Pressure dew point < 5°C / < 41°F
Residual oil content < 3.0 mg/m
3
Dimensions and connections
Dimensions (H x W x D) [mm]: 1224 * 725 * 270
Dimensions (H x W x D) [inch] 48.2 * 28.5 * 10.6
Connections: All connections: G 1”
Net weight:
NitroFlow
®
HP1
NitroFlow
®
HP2
NitroFlow
®
HP3
Kg
85
95
105
Lbs
187
209
231
Housing
Protection degree IP 44
Electrical data
Voltage/frequency 100-115-230Vac 1ph / 50-60Hz
Power consumption 30 W