EasyManua.ls Logo

Parker NitroFlow HP - 13 Appendix B: Firmware Upgrade Instructions V2.03 Nitroflow Series

Parker NitroFlow HP
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
K3.1.141e Manual NitroFlow HP_EN.doc - 58 -
13 Appendix B: Firmware upgrade instructions
V2.03 NitroFlow
®
series
Controller upgrade warning:
Do not cut the power during the upgrade process.
All log data is erased during the upgrade process (also on the SD-card).
When there is an error during the upgrade procedure, try again from the start.
In case of problems contact Parker technical support
Controller upgrade steps:
1. Switch the main Power switch OFF (consult manual)
2. Remove the SD-card (consult manual)
3. Place the latest version of the IO.bin & LCD.bin files in the root directory of the
SD-card.
4. Remove the file FORCE.txt when present.
5. Place the SD-card in the controller.
6. Switch the main Power switch ON.
7. The IO-board is now upgrading (+/- 30sec)
8. The message initialisation pops up (+/- 60sec)
9. The message software needs update 34 will appear.
10. Switch the main switch OFF & ON
11. The display starts flashing (+/- 30sec)
12. The system beeps 2 or 4 times and then starts up.
13. Enter the menu then go to the login screen.
14. Enter 943363 and press enter.
15. The message Clearing flash will appear (+/- 60sec)
16. The message “Turn the unit off” will appear.
17. Switch the main switch OFF & ON
18. The upgrade process is completed.
19. Check the customer software settings.
Software revision history:
V2.04 / 22 June 2009 - Current
- Pressure sensors range changed.
- Alarm inlet pressure above maximum.
- Romanian language.

Table of Contents