K3.1.141e Manual NitroFlow HP_EN.doc - 21 -
5 Installation
Follow the paragraphs in this chapter to install the NitroFlow
®
HP.
5.1 Transport and storage
Warning
• The NitroFlow
®
HP is heavy in weight; take appropriate safety
measures in handling and transport
• Put the NitroFlow
®
HP in the original box to transport the
NitroFlow
®
HP over longer distances.
• Lift the NitroFlow
®
HP with a forklift.
• For qualifications of personnel, refer to §2.1.
• The NitroFlow
®
HP must be transported and stored within a
temperature range between -25°C and +50°C.
5.2 Define location
Install the NitroFlow
®
HP on a fixed location. The location must meet following
requirements:
• Indoors
• Ambient temperature between 10°C and 40°C
• Dry
• No continuous direct irradiation by sunlight
• Away from heat sources
• Properly ventilated room.
• Easy accessible for operating and service
• Installation can be used up to 1000m above sea-level. In case of installations
above this height, contact your dealer, since the performance of your
equipment will reduce.