K3.1.141e Manual NitroFlow HP_EN.doc - 29 -
Symbol/data Information/result
When flashing there is an alarm; touch the symbol and the
current alarm will be shown. (refer to § 7.3.1)
Unit status (A) Can be OFF / RUN / STAND-BY / ALARM / P-RELIEF
OFF: Main switch is on but generator is not operational
RUN: Generator is operational (producing nitrogen)
STAND-BY: Generator is stopped by the option pressure switch
(PSH) or generator is waiting for remote control signal.
ALARM: Generator is stopped by an alarm
ALARM / RUN: There is an alarm but generator is still running.
P-RELIEF: The generator is doing a countdown to depressurize
and protect the system. Generator will not start if it was stopped
less then 3 minutes ago. Remaining time is shown on the
display. When the generator was stopped longer then 3 minutes
ago it will start immediately once pressing the start/stop button.
Menu button, touch to go to settings menu
Start/stop button, generator will start or stop.
To start the unit, first switch on the main switch and then touch the start
-button.
The unit status will switch to P-RELIEF. Solenoid valve Y1 will be opened three
minutes (180 seconds) after the unit was switched on. The remaining countdown
time is shown next to the text P-RELIEF.
When the unit is started and normally running the controller will show:
Actual outlet pressure
Actual oxygen or nitrogen level (when selected not to hide, refer to §6.2.7)
Flow indication (when selected not to hide, refer to §6.2.7). The flow indication
will appear after 30 seconds.