PRUNING SHEARS C45, C45-P150, C45-P200
163529-D
7. INCIDENTS AND TROUBLESHOOTING
7.1. TABLE OF INCIDENTS AND BREAKDOWNS
Caution
Never attempt to open or repair the battery pack or the charger
Problem Probable cause Check Possible action
Battery off Check that the battery is
switched on.
Switch on the battery.
Battery discharged Check that the battery is not
completely discharged.
Recharge the battery.
Problem related to the ac-
tivation/deactivation of the
Activ' Security and the pres-
ence or not of gloves PEL-
LENC.
Check the Activ' Security
activation and/or the Ac-
tiv' Security power-up pro-
cedure.
See 6.3.2. Checking the op-
eration of the Activ'Security
and the conductivity of the
gloves, page 33.
Poor connection between
tool and battery
Check that the tool is con-
nected to the battery.
See 4.7. Connecting the
tool to the ULIB 150P and
250 batteries, page 17.
The tool does not start
The power cord is cut or
faulty
Check the condition of the
power cord.
Change the power cord.
Authorised distributor PEL-
LENC.
The tool makes an unusual
noise
Internal breakage Authorised distributor PEL-
LENC
Authorised distributor PEL-
LENC.
The machine has reached
its temperature limit
Abnormally high tool tem-
perature.
Check that the tool is be-
ing used under the recom-
mended conditions.
See 2. Safety, page 7.
Internal breakage Authorised distributor PEL-
LENC
Authorised distributor PEL-
LENC.
The tool stops during use
Stop and restart the battery, if the tool still does not start, see the "tool does not start"
section of this table.
Ineffectiveness of the blade Check the sharpness of the
blade, the tightness of the
blade, the greasing of the
blade and the crossing of
the blade and hook.
See 6. Maintenance, page
31.
The cutting diameter does not correspond to the maxi-
mum capacity of the pruning shears
Cut only branches that are
suitable for your tool.
Loss of efficiency and/or
cutting quality of the tool
Battery partly discharged Check that the battery is
sufficiently charged.
Recharge the battery.
Power loss + Battery LED
flashing
Repetition of 3 XL cuts, the battery limits the power for
30 seconds.
Do not perform an XL cut for
30 seconds.
The battery displays an er-
ror code
See the operating instructions for the battery.
The blade no longer opens
in half-open position
Mode problem Check that you are in a half-
open mode
See 5.6.1.1. Presentation of
usage modes, page 26.
42