PRUNING SHEARS C45, C45-P150, C45-P200
163529-D
Problem Probable cause Check Possible action
Check the optical sensor
window
Optical sensor problem
Check the sensitivity setting
of the optical sensor
See 5.4.2. Optical sensor
and half-opening, page 24.
Trigger problem Check the trigger See 6.3.3. Checking the op-
erating trigger, page 34.
If the tool does not work, return the set in its original packaging to an authorised repairer PELLENC.
7.2. ACTIV' SECURITY LED CODES SUMMARY
Normal Codes
Start-up
Flashing red • Waiting for initialization
Red and (light) blue fixed • Activ' Security initialized: user detected on one of the
pads and on the hook
Slow flashing red • Activ'Security deactivated
Use
Steady blue • No fault detected: user detected between one of the
pads and the trigger
Flashing blue • No fault and low Activ' Security threshold: user detect-
ed between pad and trigger
Slow flashing red and alarm sound • Activ'Security deactivated
Degraded Mode codes
Use
Rapid flashing red • Poor connection between the hook and the trigger
board
1 short beep every 3 seconds • Guard open
Fault codes
Start-up
Flashing red and blue • Waiting for initialisation and user detected on one of
the pads
Use
Steady red • User not detected on one of the pads or on the trigger
Steady red and (light) blue • Fault detected: user in contact with the hook and/or not
detected on one of the pads
Steady red and flashing (light) blue • Fault detected with Activ' Security threshold low: user
in contact with the hook and/or not detected on one of
the pads
7.3. SUMMARY OF BATTERY LED CODES ON C45 PRUNING SHEARS
Fault codes
Use
Flashing with loss of tool power • Wait 30 seconds without cutting large branches.
43