Installer Manual Magnum 742-762 - Description
Ref. MKT-IM-012 / C - 25.10.2019 25 / 106
3.5.5. Hydraulic output signal
An optional hydraulic output signal is available on the valve. An optional cam lobe on pilot valve #6 is
used on the camshaft assembly to initiate the hydraulic output signal during regeneration or
backwash.
The hydraulic line pressure signal is available through the ¼" connection on the back of the valve
(marked "Aux").
Remove the tube cap installed for shipping. Install one of the available cam lobes.
P/N 1000554
Provides a hydraulic signal from the beginning of Backwash though the
start of Refill cycle.
P/N 1000553
Provides a hydraulic signal from the beginning of Backwash through
the end of Refill cycle.
P/N 1041064
Breakaway cam.
It can be programmed to send a hydraulic signal at any time during the
regeneration or backwash cycle.
The camshaft must be turning for the signal to change states (i.e.
switch from Off to On or vice versa).
Optional cam lobe position #6
(Hydraulic output signal)
Auxiliary hydraulic output port "Aux"