Installer Manual Foleo - Troubleshooting
98 / 112 Ref. MKT-IM-038 / C - 15.11.2019
Run out of
conditioned water
between
regenerations.
Improper regeneration.
Control brine dosage set and repeat
regeneration.
Incorrect brine setting.
Set brine to proper level.
See 5.4.3. Valve screen, page 54.
Incorrect hardness or capacity
settings.
Set hardness and capacity settings.
See 5.4.4. Feed Water Hardness (H),
page 42 and 5.5.6. Unit capacity (C),
page 45.
Water hardness has increased.
Check hardness settings.
See 5.4.4. Feed Water Hardness (H),
page 42.
Restricted meter turbine rotation due
to foreign matter in meter.
Remove meter housing, free up
turbine and flush with clean water.
Turbine should spin freely. If not,
replace meter.
Too much water used between the first
cycle of regeneration and brine draw.
Set regeneration times at low or no
water usage.
See 5.4.4. Regeneration screen,
page 56.
Eventually installing the optional
Pentair
®
fast brine valve will be
necessary. Contact your supplier.
Brine tank
overflow.
Air leak in brine line.
Check all connections in brine line for
any leaks.
Incorrect BLFC size with regards to
injector size.
Use of too small BLFC with large
injector will reduce draw rates.
BLFC/DLFC causing inconsistent brine
draw clogged with resin or other
debris.
Clean BLFC & DLFC.
Incorrect controller settings.
Check that controller setting match
with your actual softener model and/or
valve configuration.
Injector plugged causing refill instead
of drawing.
Clean injector.
See 8.5.4. Injector and injector screen
cleaning, page 80
Issue Cause Reset and recovery