Installer Manual Foleo - Troubleshooting
Ref. MKT-IM-038 / C - 15.11.2019 99 / 112
Brine tank
overflow.
Valve fails to draw brine in brine draw
cycle.
Check for seals & spacers integrity.
Clean or replace if necessary.
Check upper screen cleanliness. Clean
or replace if necessary.
Check inlet pressure. Make sure it is
above 1.4 bar dynamic.
Check safety brine valve and air check.
Clean, repair or change if necessary.
Check for leak/air intake in brine line.
Change if necessary.
Check if brine line is not plugged or
partially obstructed. Remove plug if
necessary.
Check if drain line is not plugged or
partially obstructed. Remove plug if
necessary.
Issue Cause Reset and recovery