Installer Manual Riversoft - Safety
Ref. MKT-IM-045 / A - 13.03.2020 11 / 90
2.4.2. Hygiene measures
DANGER
Do not use with water that is micro-biologically unsafe or of unknown quality without
adequate disinfection before or after the softener.
WARNING
Water softeners using sodium chloride for regeneration will add sodium to the water.
Person who are on sodium-restricted diets should consider the added sodium as part of
their overall sodium intake.
Disinfection
The materials used for the construction of our products meet the standards for use with potable
water; the manufacturing processes are also geared to preserving these criteria. However, the
process of production, distribution, assembly and installation, may create conditions of bacterial
proliferation, which may lead to odour problems and water contamination;
it is therefore strongly recommended to sanitize the products. See 6.2. Cleaning, disinfection and
sanitization, page 53;
maximum cleanliness is recommended during the assembly and installation;
for disinfection, use sodium or calcium hypochlorite and perform a manual regeneration.