8.5.3. Brine tank and brine well cleaning
No. Operation
A Remove the softener cover (1).
B Open the brine tank cover (4).
C Remove the remaining salt from brine tank (5).
D Remove the brine well cover (3).
E Remove the remaining brine from brine well (2).
F Clean the brine tank (5) and the brine well (2) with water and sponges.
CAUTION
Do not lay down or flip over the softener to empty the brine tank.
G
Using a water vacuum, remove the cleaning waste and remaining water from brine tank
(5) and from brine well (2).
H Refit the brine well cover (3).
I Fill the brine tank (5) with salt, see 8.3. Adding salt, page 60.
J Close the brine tank cover (4).
K Refit the softener cover (1).