Installer Manual Riversoft - Operation
56 / 90 Ref. MKT-IM-045 / A - 13.03.2020
7.2.2. Immediate regeneration
A Press and hold for 3 seconds to initiate immediate manual regeneration.
→ The controller will display a cascading symbol "--" as it cycles to backwash.
→ The controller will proceed through a complete regeneration.
7.2.3. To advance regeneration cycles
A Simultaneously press and to advance to the next cycle.
→ When the camshaft reaches the next cycle, "C#” will be displayed.
B Repeat and to advance through each cycle.
7.2.4. To cancel a regeneration
A Press and hold and for 3 seconds during any regeneration cycle to cancel it.
→ The controller will skip the remaining regeneration cycles and return to the service position.
It may take 1 to 2 minutes.
→ The time of day will be displayed when the controller reaches the service position.
7.3. Operation during a power failure
All the program settings are stored in a permanent memory (NOVRAM);
current valve position, cycle step time elapsed, and time of day are stored during a power failure,
and will be restored upon power restoration;
time of day/day of week is kept during a power outage thanks to a supercapacitor as long as the
power is restored within 8 hours and the supercapacitor was fully charged. Multiple power
shutdown in a short period may decrease the supercapacitor charge;
the time of day on the main display screen will flash for 5 minutes when there has been a power
failure. The flashing of the time of day can be stopped by pressing any button on the display;
should the power failure be longer than 8 hours, the display will show "0". To show the time, it
must be set up again and restart internally as if it was 12:00 when power was restored.