8.5.5. Cleaning injector and injector screen
No. Operation
A Remove the softener cover, see 8.5.2. Covers removal (softener and valve), page 63.
B Using a Torx key, unscrew and extract the injector cap (3).
CAUTION
Take care not to damage the injector (2).
C Using pliers, gently extract the injector (2) from valve body.
D Unclip the injector screen (1) from the injector (2).
E Clean the injector (2) using compressed air, a soft brush or possibly a pin.
F Clean the injector screen (1) with a soft brush.
NOTE
Use of descaling agent such as white vinegar might be required in case of impurities or
scale on the injector screen (1) and on the injector (2).
G Check for o-rings integrity.
H Assemble the injector screen (1) on the injector (2).
I Rinse thoroughly any cleaning agent you may have used.
J Reverse above procedure steps to rebuild.