5.3. Quick program guide
5.4. Time of day
Set the current time.
Parameter
description
Range of values
Default
value
Units of
measure
Notes
Time of day 0:00 - 23:59 12:00
hour:
minute
Brine dosage 0.2 - 6.0 0.6 kg
From 0.2 kg to 1.0 kg by increments
of 0.05 kg;
from 1.0 kg to 3.0 kg by increments of
0.1 kg;
from 3.0 kg to 6.0 kg by increments of
0.5 kg.
Volumetric
regeneration
0.4 - 9.5 3.6
m
3
From 0.4 m
3
to 1.0 m
3
by increments
of 0.05 m
3
;
from 1.0 m
3
to 3.0 m
3
by increments
of 0.1 m
3
;
from 3.0 m
3
to 5.0 m
3
by increments
of 0.2 m
3
;
from 5.0 m
3
to 9.5 m
3
by increments
of 0.5 m
3
.
Calendar override 0 - 30 3 day
0 = Disabled;
0.3 = Regeneration every 8 hours: at
2, 10 and 18 hours;
0.5 = Regeneration every 12 hours: at
2 and 14 hours;
1 - 30 = Regeneration every X days.
System selection 1 - 4 1 -
See 5.10. Regeneration cycles time,
page 48.
A Press until desired hour appears then release.
→ Range from 0 through 23 hours.
→ The elapsed minutes will reset to zero when the hours are