Installer Manual Riversoft - Maintenance
Ref. MKT-IM-045 / A - 13.03.2020 69 / 90
8.5.7. Other wear and tear parts
8.5.7.1 Cleaning the backwash flow controller
No. Operation
NOTE
The following procedure is only applicable in the bypass configuration.
A Remove the softener cover, see 8.5.2. Covers removal (softener and valve), page 63.
B Remove the clip (1).
C Unscrew the backwash controller (4) by hand.
CAUTION
Pay attention to not lose the backwash controller ball (3) that is inside.
D Clean the backwash controller (4) using a soft brush or compressed air.
E Clean the backwash controller grooves and backwash controller chamber (2).
F Reverse above procedure steps to rebuild.
NOTE
Remember to put the backwash controller ball (3) inside the plug when reassembling.
CAUTION
When reassembling the backwash controller (4), slowly screw by hand.