Installer Manual Riversoft - Maintenance
Ref. MKT-IM-045 / A - 13.03.2020 59 / 90
* Electronic parts - durability strongly affected by power source quality and stability.
** Elastomer durability is strongly affected by raw water concentration in chlorine and its derivative.
*** 368 being not equipped with an Aircheck, therefore the safety brine valve should be equipped with and aircheck.
**** Wear part.
8.2.1. Maintenance instructions
Disinfect and clean the system at least once a year or if the treated water has an off-taste or an
unusual odour;
Optical sensor Check Check Check Check Replace
Inlet hardness Check Check Check Check Check
Residual
hardness
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Check/adapt
mixing screw if
necessary
Electronic/
settings*
Check Check Check Check
Check/ replace
if necessary
Transformer* Check Check Check Check
Check/ replace
if necessary
Turbine
manifold****
Check and
Clean
Check and
Clean
Check and
Clean
Check and
Clean
Replace
Turbine cable Check Check Check Check Replace
Valve
watertightness
Check Check Check Check Check
Valve to piping
watertightness
Check Check Check Check Check
Brine tank &
brine well
Clean Clean Clean Clean Clean
Safety brine
valve (if
present)
Check and
Clean
Check and
Clean
Check and
Clean
Check and
Clean
Check and
Clean
Brine tube Clean Clean Clean Clean Clean
Brine line Clean Clean Clean Clean Clean
Cabinet body
and cover
(external)
Clean Clean Clean Clean Clean
Items 1 year 2 year 3 year 4 year 5 year