Installer Manual Riversoft - Programming
Ref. MKT-IM-045 / A - 13.03.2020 47 / 90
5.5. Brine dosage
Set the brine dosage.
5.6. Volumetric regeneration
Set the capacity in [m
3
] between each regeneration.
5.7. Time clock regeneration (Riversoft 4 only)
Set the time between each regeneration.
A Press until desired brine dosage appears then release.
→ Range from 0.2 kg to 6.0 kg;
from 0.2 kg to 1.0 kg by increments of 0.05 kg;
from 1.0 kg to 3.0 kg by increments of 0.1 kg;
from 3.0 kg to 6.0 kg by increments of 0.5 kg.
A Press until desired capacity appears then release.
→ Range from 0.4 to 9.5 m
3
;
from 0.4 m
3
to 1.0 m
3
by increments of 0.05 m
3
(12 increments);
from 1.0 m
3
to 3.0 m
3
by increments of 0.1 m
3
(20 increments);
from 3.0 m
3
to 5.0 m
3
by increments of 0.2 m
3
(10 increments);
from 5.0 m
3
to 9.5 m
3
by increments of 0.5 m
3
(10 increments).
A Press until desired interval appears then release.
→ Range from 0 through 30;
0 = Disabled;
0.3 = Regeneration every 8 hours: at 2, 10 and 18 hours;
0.5 = Regeneration every 12 hours: at 2 and 14 hours;
1 - 30 = Regeneration every X days (every 3 days in this
example).