Adjustment
11 - 18
61-035
11.04.14 Height of the feed wheel on the PFAFF 591
Requirement
The feed wheel should protrude from the needle plate by tooth height (approx. 0.8 mm)
1
2
3
Swing out the roller presser.
Loosen screws 1.
Adjust eccentric 3 (fastening screw accessible through hole 2) according to the
requirement.
Tighten screws 1.
Fig. 11 - 14
61-039
0.8 mm