Adjustment
11 - 19
61-036
11.04.15 Stitch length control eccentric
Requirement
When the needle (with maximum stitch length set), coming from TDC, is 3 mm above the
needle plate, the crank 3 must have reached its front point of reversal.
2
Set the maximum stitch length.
Turn stitch length control device 1 (screws 2) according to the requirement.
Fig. 11 - 15
1
3