16
Sewing with light barrier / D+
If the "TE / Input key" is switched off, the sewing with light barrier functions is switched
on or off. When sewing with light barrier, the number of stitches entered corresponds to
the light barrier compensation stitches.
If the "TE / Input key" is switched on, this function key serves as a plus function for the
setting range (D).
F1 / D-
If the bobbin thread is monitored by stitch counting, the counter is reset after "Bobbin" is
displayed on the monitor. Afterwards the next counting operation begins.
If the "TE / Input key" is switched on, this function key serves as a minus function for the
setting range (D-).
For control unit P45 PD2-L other functions can be allocated to this key with parameter
"488" (see Chapter 9.03 Parameter input).