P74 ED Input
53
Group
Parameter
Description
User level
Setting range
Set value
1
154 End tack
(when parameter 523 is set at "1")
ON = ornamental tack,
OFF = standard tack
B ON - OFF ON
157 Third seam section at start of decorative back-
tack
B ON - OFF OFF
160 Function selection for knee switch
0 = Function off
1 = Stroke adjustment manual
2 = Feed reverse manual
B 0 - 2 1
199 Speed for light barrier compensating
stitches
B 300 - 6400 1200
2
201 Emission power of laser diode on
bobbin thread monitor
( 0 = off, 255 = maximum light)
B 0 - 255 100
206 Interrupt /stop seam section at fi xed speed
ON = with pedal -2,
OFF = with pedal 0
B ON - OFF OFF
218 Interruption of programmed
seam with pedal -2.
Off = possible,
On = not possible
B ON - OFF OFF
219 Poti for stroke adjustment
ON = activated, OFF = off
B ON - OFF ON
263 Number of stitches with additional thread
tension
B 0 - 20 0
3
303 Needle position at end of seam section with
end tack without trimming
ON = lowered, OFF = raised
B ON - OFF OFF
307 Delay time till switching off output
"needle cooling" after the machine stops
B 0 - 2000 50
311 Stop stitch counting
ON = with thread trimming
OFF = without thread trimming
B ON - OFF OFF