PEC Plus user manual Programming target temperatures
31040003 45
Parameter Description Options/range Displayed as
1 – Current day The current day of the growth curve 0 to 365 coff to c365
2 – Step The step of the growth curve you are
programming
1 to 7 stp1 to stp7
3 – Duration The duration of the step you are
programming
0 to 365 d 0 to d365
4 – Start temperature The starting temperature for the step
you are programming
32.0 to 99.9°F
(0.0 to 37.7°C)
t32..0 to t99.9
t 0.0 to t37.7
5 – Group set point If the growth curve is not enabled, the
control uses this as the target
temperature.
32.0 to 99.9°F
(0.0 to 37.7°C)
t32..0 to t99.9
t 0.0 to t37.7
To enable, disable, or change the current day of the growth curve
1. Press Function until the LED for GROWTH CURVE is lit.
The display shows para (parameter A).
2. Press 1.
The current day of the growth curve is displayed.
To enable (when it is disabled) or change the current day of the
growth curve, press Up or Down to set the current day.
To disable the growth curve, press Down to set the current day
to off.
3. Press Select to return to the Parameter menu.
4. Press Back to return to the main display.
To program the growth curve
1. Press Function until the LED for GROWTH CURVE is lit.
The display shows para (parameter A).
2. To view the current step, press
2.
The display shows the current step.
3. To choose the step you want to program, press Up or Down and
then press Select.
The control returns to the Parameter menu
4. To view the step duration, press
3.
The display shows the current setting.
5. To change the duration, press Up or Down and then press Select.
The control returns to the Parameter menu.
stp3
GROWTH CURVE
c20
T745
coff
GROWTH CURVE
c020