Appendix A Understanding the Home Screen Metrics
Blockage Monitoring Metrics Defined
Note: “Product” will be replaced by system’s nickname as defined by the user.
“Product” Magnitude
A relative measurement comparing the amount of a product being applied in a given area.
Value Range: 0-10,000 k
Use Case: A row by row comparison of the amount of product being applied.
Available Widgets:
User inputs: Set by grower inputting a target on the granular control page (i.e. 360 lb/acre), and
alerts/alarm being driven by percentages; alerts options - 10%, 20%, 30%, 40%, Custom,
Disabled.
“Product” Uniformity
A measure of how uniform the product magnitude is across the implement.
Row uniformity: % difference of that row compared to average magnitude across implement
Implement uniformity: average of all row uniformity percentages across the entire implement
Value range: 0-100%; 100% is perfect
Use Case: An overall measurement for uniformity, but also will pick up which rows are the
worst.