ID Description
Ramp Pivot Cover
Specifications
System Component Specification
Ramp Hinge Pivot Bolts 1080 in-lbs (90 ft-lbs or 122 Nm)
Procedure
Review entire procedure before starting.
Removal Instructions
This procedure will require a fully charged good battery to operate the lift motor.
IMPORTANT: It's important to follow the removal steps in sequence to successfully
remove the ramp.
1. Access the service menu diagnostic CrossRamp Test and set the incline level to 1.
a. On LED P10, P30, P30i and P31 consoles: (Service menu (51765761) >
MACHINE TEST > CROSSRAMP TEST and set the INCLINE LEVEL to 1).
b. On P62, P80, and P82 consoles: (Service menu (51765761) > System Set-
tings > System Tests > CrossRamp Test and set the INCLINE level to 1).
2. Disconnect the Lift Motor input power/control cable connector.
WARNING:Make sure to disconnect the Lift Motor input power/control cable or it is
possible for the crossramp to automatically lower to level 1 under certain cir-
cumstances, such as, if the CrossRamp Test is exited or the console powers down.
This unexpected action could cause personal injury.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 96
6 Replacement Procedures
Covers and Panels Replacement