4. Use a 1/2" socket to loosen the first stage belt tensioner and walk the first stage drive
belt off the smaller first stage Step-up Pulley. Rest the belt on the Input Drive pulley, it is
not necessary to remove the belt from the Input Drive.
5. Use a 1/2" socket to loosen the second stage belt tensioner and walk the second stage
drive belt off the Generator/Eddy Brake assembly pulley and larger second stage Step-
up Pulley/Tensioner assembly pulley. Remove the second stage drive belt. Retain belt
for installation.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 137
6 Replacement Procedures
Generator/Brake Assembly Replacement