6. Use a 1/2" socket to remove the Generator/Eddy Brake assembly lower carriage bolt.
Then slide the Generator/Eddy Brake assembly downward and remove the upper car-
riage bolt. Remove the Generator/Eddy Brake assembly from the Step-up Pul-
ley/Tensioner assembly. (missing or bad snippet)
TIP: Remove the lower carriage bolt fastener first and then the upper. The upper
bolt cannot be removed while the lower bolt is installed.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Page 138
6 Replacement Procedures
Generator/Brake Assembly Replacement