11. Select the option
‘End’
and then press the key
[P/OK]
- the pump
changes to a continuous display.
ð
The pump is calibrated.
The corresponding continuous displays indicate the calibrated
values.
8.6.3
Settings for the “Metering” function (DOSING menu)
The "Dosing" menu has the following sub-menu:
1 -
‘Dosing profile’
8.6.3.1
Settings in the sub-menu ″Dosing″
Dosing
Main menu
Mode
Settings
Service
Information
Language
Settings
Analog
Auxiliary freq.
Calibrate
Dosing
Relay
Dosing profile
End
Dosing profile
Standard
Discharge opti.
Suction opti.
Continuous
display
Under
‘Dosing
è
Dosing profile’
you can precisely match the pump
metering flow over time against the requirements of the particular applica‐
tion, see Chapter "Function Description".
Under
‘Dosing profile’
-
‘Discharge opti.’
, the discharge stroke is elon‐
gated, the suction stroke is executed as quickly as possible. This setting is
suitable for example for those applications that require optimum mixing
ratios and as continuous as possible chemical mixing.
Under
‘Dosing profile’
-
‘Suction opti.’
, the suction stroke is elongated as
much as possible, which makes possible a precise and problem-free
dosing of viscous and gaseous media. This setting should also be chosen
to minimise the NPSH value.
Discharge opti.
Suction opti.
Set-up
56