Data Value Unit
Switch on peak current, (for approx. 100
ms)
4 A
Electrical data at 230 V
Data Value Unit
Switch on peak current, (for approx. 100
ms)
8 A
Fuses
Fuse Value Part no.
Fuse, internal 3.15 AT - (1.5 kA) 732414
Only use the original fuses from ProMinent! It is not sufficient
to use a fuse with the above fuse rating.
14.7
Diaphragm rupture sensor
Contact loading, max.
at voltage Maximum current
30 V DC 1 A
The contact is an opener.
The contact is an potential-free.
–
For safety reasons we recommend connecting to a pro‐
tective low voltage, e.g. in accordance with EN 60335-1
(SELV ).
–
The cable can be poled as required.
14.8
Relay
The technical data for the relay are contained in the chapter
"Installation, electrical".
14.9
Sound pressure level
Sound pressure level LpA < 70 dB in accordance with EN ISO
20361:2010-10
at maximum stroke length, maximum stroke rate, maximum back pressure
(water)
Contact (standard)
Sound pressure level
Technical data
83