Technical data
14.1
Performance data
Type Minimum pump capacity at maximum
back pressure
Maximum
stroke
rate
Suction
lift
Permis‐
sible pri‐
ming pres‐
sure,
suction
side
Connector
size
bar psi l/h gph Strokes/
min
ml/stroke m WS bar R"-DN
12017 PVT 12 174 20 5 88 3.9 7 1 3/4" - 10
12017 SST 12 174 20 5 88 3.9 7 1 3/4" - 10
12035 PVT 12 174 42 11 172 4.1 7 1 3/4" - 10
12035 SST 12 174 42 11 172 4.1 7 1 3/4" - 10
10050 PVT 10 145 49 13 200 4.1 7 1 3/4" - 10
10050 SST 10 145 49 13 200 4.1 7 1 3/4" - 10
10022 PVT 10 145 26 7 88 5.1 6 1 3/4" - 10
10022 SST 10 145 26 7 88 5.1 6 1 3/4" - 10
10044 PVT 10 145 53 14 172 5.1 6 1 3/4" - 10
10044 SST 10 145 53 14 172 5.1 6 1 3/4" - 10
07065 PVT 7 102 63 17 200 5.3 6 1 3/4" - 10
07065 SST 7 102 63 17 200 5.3 6 1 3/4" - 10
07042 PVT 7 102 50 13 88 9.6 3 1 1" - 15
07042 SST 7 102 50 13 88 9.6 3 1 1" - 15
04084 PVT 4 58 101 27 172 9.8 3 1 1" - 15
04084 SST 4 58 101 27 172 9.8 3 1 1" - 15
04120 PVT 4 58 117 31 200 9.8 3 1 1" - 15
04120 SST 4 58 117 31 200 9.8 3 1 1" - 15
All figures refer to water at 20 °C.
The suction lift applies to filled suction line and filled liquid end - when
installed correctly.
Data Value Unit
Reproducibility ±2 % *
* - when installed correctly, under constant conditions, at least 30 %
stroke length and water at 20 °C
S1Cb
Accuracies
Technical data
80

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent S1Cb and is the answer not in the manual?

ProMinent S1Cb Specifications

General IconGeneral
BrandProMinent
ModelS1Cb
CategoryWater Pump
LanguageEnglish

Related product manuals