37
Managing the Pegasus R4iPegasus R4i Product Manual
Controller Settings
To modify controller settings:
1. From the Device menu, choose Component List.
2. Mouse-over the controller, then click the Settings button.
Make setting changes as required:
• Enter, change or delete the alias in the Alias eld.
• SMART Log – Check the box to enable or uncheck to disable.
• SMART Polling Interval –Enteravalueintotheeld,1to1440minutes.
1440 minutes = 24 hours
• Enable Coercion – Check the box to enable or uncheck to disable.
• Coercion Method – Choose a method from the dropdown menu:
• GBTruncate
• 10GBTruncate
• GrpRounding
• TableRounding
• Write Back Cache Flush Interval –Enteravalueintotheeld,1to12seconds.
• Enclosure Polling Interval – 15 to 255 seconds.
• Adaptive Writeback Cache – Check the box to enable or uncheck to disable.
• Forced Read Ahead – Check the box to enable or uncheck to disable.
3. Click the Save button.
4. Click the X icon to close the settings panel.