176
Vess A Class NVR Storage Appliance Promise Technology
Examples
rc
rc -a start -l3 -n -p
rc -a start -l3
rc -a stop -l2
rb
Usage
rb [-a <action>] [-d <DaId>] [-s <SeqNo>]
rb -a start -d <DaId> -s <SeqNo> -p <PdId>
rb -a stop -d <DaId> -s <SeqNo>
rb -a pause -d <DaId> -s <SeqNo>
rb -a resume -d <DaId> -s <SeqNo>
Summary
The rb command starts, stops, pauses, and resumes a Rebuild and monitors the progress of a
running Rebuild.
Note that the replacement drive must be the same media type, HDD or SSD, as the other
physical drives in the disk array.
Options
-a <action> Species action to perform.
list (Default) Displays the running and paused Rebuilds and their status.
start Starts a manual Rebuild.
stop Stops a Rebuild.
pause Pauses a Rebuild.
resume Resumes a paused Rebuild.
-d <DA ID> Species which disk array on which to perform the Rebuild.
-s <sequence Num> Species the sequence number of the failed physical drive. The source
drive of the Rebuild.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology Vess A3340 and is the answer not in the manual?

Promise Technology Vess A3340 Specifications

General IconGeneral
BrandPromise Technology
ModelVess A3340
CategoryNetwork Hardware
LanguageEnglish

Related product manuals