User Interfaces SFC6400A/SFC1450A Synthesized Frequency Upconverter
4-14 TM106 – Rev. 1.1
REMOTE PORT:
REMOTE PRTOCOL: {ASCII, RLLP}
Allows the user to set the remote port communication
protocol.
REMOTE ADDR: {32 - 255 RLLP, 1 – 255 ASCII}
Allows the user to set the communication address of the
remote port.
REMOTE BAUD: {2400, 9600, 19200}
Allows the user to set the baud rate for remote port
communication.
ECHO MODE: {OFF, ON}
Allows the user to control whether the input at the
terminal is echoed back. Only valid in Remote ASCII
Mode.
REMOTE LINE: {RS-232, RS-485}
Sets the interface type of the remote port.
HW/FW CONFIG:
FIRMWARE: FW/XXXX - - Version Y.YY
Displays the revision number of the installed M&C
Firmware (where XXXX is the firmware number and Y.YY is
the version).
FW/XXXX - - 19DEC2002
Displays the revision number and release date of the
installed M&C Firmware.
CPLD VERSION: {x.x}
Displays version number of installed CPLD Firmware.
FPGA VERSION: {x.x}
Displays version number of installed FPGA firmware.
HARDWARE:
CONVRTR CONFIG: {STAND ALONE, PRIMARY 1F1, BACKUP 1F1,
PRIMARY 1 - 8 1F8, BACKUP 1F8}
Allows the user to indicate the function of the Converter as
it is connected in the system. The M&C determines this
by reading 4 ID bits through the switch interface (refer to
Section 5.10).
CONVERTER ID: {1 - 11, 15}
Displays a decimal version of the binary ID bits described
above and in Section 5.10. The individual bits are
strapped high or low at the switch. They are decoded as
follows.