MEMory Subsystem EM510
5.45 4065.7763.32-01.00
. . :MPAR <name>,<ACT>
Setting the memory location parameter (MPAR = MemoryPARameter) <ACT> .
Parameters:
<name> MEM0 to MEM9999 | CURRENT
<ACT> setting/resetting the memory to the scan (ON/OFF or 1/0)
Example:
MEMory:CONTents:MPAR MEM1, OFF
. . :MPAR? <name>
Query about memory-location parameter <ACT>.
Parameters:
<name> MEM0 to MEM9999 | CURRENT
Result:
<ACT> set/reset for scan (1/0)
Example:
MEMory:CONTents:MPAR? MEM1 -> 0
. :EXCHange <name1>, <name2>
Exchange of contents of two memory locations.
Parameters:
<name1> MEM0 to MEM9999 | RX | CURRENT
<name2> MEM0 to MEM9999 | RX | CURRENT
Example:
MEMory:EXCHange MEM123, RX