CHAPTER 3
34 SmarTrax™ MD Calibration & Operation Manual
Use the scroll button at the bottom of the Diagnostics prompt to toggle between the following PWM values and
steering system settings and options:
Disengage Sensitivity - Proper tuning of the disengage sensitivity value allows the equipment operator to
disengage SmarTrax MD by turning the steering wheel with minimal or moderate effort. Disengage sensitivity
requires minimal adjustment.
NOTE: If the sensitivity value is too low, the steering system may disengage in rougher fields without any
input from the operator. Raising the sensitivity value too high may make disengaging the SmarTrax
MD system at the steering wheel difficult or impossible.
Target Current and Actual Current - Current readings performed on SmarTrax systems MD. Target Current is
what the system expects to read. Actual Current displays the amount of current the system is using to steer the
machine. These values are used to adjust system performance.
Current Compensation - This feature is not used in SmarTrax MD systems.
Anti-Oscillation-Articulated Machines - This feature is not used in SmarTrax MD systems.
SENSOR STATUS
Edit
SmarTrax MD Sensor Status
Zero Yaw