4
P/N 016-5030-020 Rev. D 57
VIPER PRO CALIBRATION AND OPERATION
FIGURE 27. SPS Calibration Screen
3. Turn the steering wheel fully to the right wheel lock.
4. Select Right.
5. Select Next.
CALIBRATE THE MACHINE’S STEERING SYSTEM
After the initial calibration of the SmarTrax MD system is complete, it is necessary to calibrate the machine’s
steering system. This allows the SmarTrax MD system to learn the steering capabilities of the machine to allow
SmarTrax MD to properly steer it in the field.
Before beginning the machine’s steering system calibration, ensure:
• The implement sections are folded in and the booms are racked.
• The machine’s engine is running at the normal operating RPM.
• The machine’s measurements are correctly entered into the Viper Pro.
WARNING
The machine’s wheels will turn automatically. Be
sure the area around the vehicle is clear of
people and equipment before engaging the
steering system.