CHAPTER 4
64 SmarTrax™ MD Calibration & Operation Manual
FIGURE 36. SmarTrax MD Controller and System Diagnostics Screens
Input Sensors - Displays sensor calibration values.
Steer Switch and Foot Switch - Displays the state of the disengage switch/transducer and foot/engage
switches. Lower-case letters indicate that there is no input from the switches. Upper-case letters indicate
activation of the switches.
Message Frequency - Displays GGA input message rate.
Node Information - Displays node hardware version, software version, and serial number.
Exit - Returns to the SmarTrax MD Controller screen.
Machine DB - The database stores the information that was entered into the Viper Pro during initial startup. In
the SmarTrax MD system, there is only one database version.
FIGURE 37. System Diagnostics and PWM Setup Screens
PWM Values - Displays SmarTrax MD PWM minimum, maximum, and gain values. Adjustment of these values
is not typically necessary. Raven Industries recommends leaving these values as configured by the

Table of Contents