30 ST60+ Graphic Display Owner’s Handbook
To connect to your NMEA IN and NMEA OUT connectors:
• Prepare the cable for connection to the ST60+ Graphic Display, as in the fol-
lowing illustration, then crimp a spade connector to each wire.
• For cables connecting to external products from other manufacturers, ensure
a ferrite is fitted to each cable, adjacent to the ST60+ Graphic Display.
• Push the spade connectors onto the appropriate connector pins of the NMEA
connectors.
• If you are connecting the
NMEA OUT connector to an external NMEA prod-
uct, connect each end of the cable shield to RF ground.
I
Supported NMEA data
SeaTalk to NMEA 0183
Data from SeaTalk is transmitted to the
NMEA OUT connector every 2 seconds.
The supported NMEA output data is detailed in the following table.
CAUTION: Connections to other equipment
If you are connecting any Raymarine product to other equip-
ment, using a non-Raymarine cable, you MUST fit an appropriate
suppression ferrite to the cable near to the Raymarine product.
Data NMEA Header
Depth DBT
Heading, deviation and variation HDG
Magnetic heading HDM
Water temperature MTW
Wind speed and angle MWV
Water speed and heading VHW
3 mm
6 mm
50 mm
(a)
(b)
D8868-1
For NMEA OUT, connect shield to RF ground
81268_3.book Page 30 Tuesday, August 1, 2006 8:05 AM