138
The temperature sensor of the
forming unit has failed.
Call in the technical department.
The temperature sensor of the
sealing unit has failed.
Analog input sensor 1 has failed.
Check wiring and connectors.
Analog input sensor 1 has failed.
Check wiring and connectors.
RE20 stopped after
number of strokes.
The machine has reached the
number of strokes set.
This is normal. See paragraph
4.4.7 for setting the number of
strokes.
AUX. 1 is giving no signal.
Call in the technical department.
Filler 2 is giving no signal.
The machine is waiting for a
signal from the AUX.1 before
proceeding
This is normal. Wait for the
message to disappear.
Call in the technical department.
Waiting for AUX. 2 signal
The machine is waiting for a
signal from the AUX. 2 before
proceeding.
This is normal. Wait for the
message to disappear.
It takes too long to reach the set
value, for vacuum pressure.
Call in the technical department.
It is taking too long to reach the
set value, for gas pressure.
Check gas pressure in system,
or contact technician.
Call in the technical department.
Safety Cover Form station rear
is open
The safety cover at the back of
the forming station (the infeed
side) is open.
Place the cover in its proper
position (see paragraph 4.2.1)
and start the machine up as
specified in paragraph 5.2.5.2.
Safety Cover Form station front
is open
The safety cover at the front of
the forming station (the out-feed
side) is open.
Safety Cover Seal station rear
is open
The safety cover at the back of
the sealing station (the infeed
side) is open.
Safety Cover Seal station front
is open
The safety cover at the front of
the sealing station (the out-feed
side) is open.
Safety Cover Cross cutting rear
is open
The safety cover at the back of
the cross cutting unit (the infeed
side) is open.
Safety Cover Cross cutting mid
is open
The safety cover in the middle of
the cross cutting unit is open.
Safety Cover Cross cutting
front is open
The safety cover at the front of
the cross cutting unit (the out-feed
side) is open.
Safety Cover rotating knives is
open
The safety cover over the rotating
knives is open.
One of the safety covers is open.
Press reset and transport
button
The film transport has stopped
before end of index length.
Control safety covers, if
necessary remove product or
film where it is touching a cover,