EasyManuals Logo

REXROTH MKD071B-061 User Manual

REXROTH MKD071B-061
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #21 background imageLoading...
Page #21 background image
Synchronous Motors MKD Safety Instructions for Electric Drives and Controls 3-5
DOK-MOTOR*-MKD*******-PR07-EN-P Version7.0 19.05.2004
3.5 Protection Against Contact with Electrical Parts
Note: This section refers to equipment and drive components with
voltages above 50 Volts.
Touching live parts with voltages of 50 Volts and more with bare hands
or conductive tools or touching ungrounded housings can be dangerous
and cause electric shock. In order to operate electrical equipment,
certain parts must unavoidably have dangerous voltages applied to
them.
DANGER
High electrical voltage! Danger to life, severe
bodily harm by electric shock!
Only those trained and qualified to work with or on
electrical equipment are permitted to operate, maintain
or repair this equipment.
Follow general construction and safety regulations
when working on high voltage installations.
Before switching on power the ground wire must be
permanently connected to all electrical units according
to the connection diagram.
Do not operate electrical equipment at any time, even
for brief measurements or tests, if the ground wire is
not permanently connected to the points of the
components provided for this purpose.
Before working with electrical parts with voltage higher
than 50 V, the equipment must be disconnected from
the mains voltage or power supply. Make sure the
equipment cannot be switched on again unintended.
The following should be observed with electrical drive
and filter components:
Wait five (5) minutes after switching off power to allow
capacitors to discharge before beginning to work.
Measure the voltage on the capacitors before
beginning to work to make sure that the equipment is
safe to touch.
Never touch the electrical connection points of a
component while power is turned on.
Install the covers and guards provided with the
equipment properly before switching the equipment on.
Prevent contact with live parts at any time.
A residual-current-operated protective device (RCD)
must not be used on electric drives! Indirect contact
must be prevented by other means, for example, by an
overcurrent protective device.
Electrical components with exposed live parts and
uncovered high voltage terminals must be installed in a
protective housing, for example, in a control cabinet.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the REXROTH MKD071B-061 and is the answer not in the manual?

REXROTH MKD071B-061 Specifications

General IconGeneral
BrandREXROTH
ModelMKD071B-061
CategoryEngine
LanguageEnglish

Related product manuals