23.
Wait 5 minutes
to ensure that no residual voltage remains on the drum.
NOTE:
The process control self check (step 28) must be performed
when there is no residual voltage on the drum.
24. Open SP Special Feature P-1.
25. Confirm that the PID key [C] is selected for the Process Control Mode
Selection. If not, touch the PID key [C].
26. Touch the Index key [D].
27. Open SP Test Mode P-4 (Process Control Self Check).
28. Touch the Process Control Self Check Start key [C]. After the self check
is completed, the machine stops automatically.
+
CAUTION
While process control is taking place, do not touch the knob, drum
stay, or drum shaft. These parts and the fly wheel carry a high voltage
during process control.
29. Touch the Index key [D].
[C]
[D]
[D]
[C]
A172/A199 5-18 SM