Bit Switches - 4
D418 120 SM
G3 Switch 0A (SP No. 1-105-011)
No Function Comments
1 1 Not used
2
Select cancellation of high-speed RX
if carrier signal lost while receiving
0: Off
1: On
This switch setting determines if
high-speed receiving ends if the carrier
signal is lost when receiving during
non-ECM mode
3 Not used Do not change the settings
4
Maximum allowable frame interval
during image data reception.
0: 5 s 1: 13 s
This bit set the maximum interval
between EOL (end-of-line) signals and
the maximum interval between ECM
frames from the other end.
Try using a longer setting if error code
0-21 is frequent.
5 Not used Do not change the settings.
6
Reconstruction time for the first line in
receive mode
0: 6 s 1: 12 s
When the sending terminal is controlled
by a computer, there may be a delay in
receiving page data after the local
machine accepts set-up data and sends
CFR. This is outside the T.30
recommendation. But, if this delay
occurs, set this bit to 1 to give the
sending machine more time to send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line
should come within 5 s of CFR.
7 Not used Do not change the settings.
G3 Switch 0B Not used (do not change the settings).
G3 Switch 0C Not used (do not change the settings).

Table of Contents

Other manuals for Ricoh Aficio MP 8001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh Aficio MP 8001 and is the answer not in the manual?

Ricoh Aficio MP 8001 Specifications

General IconGeneral
BrandRicoh
ModelAficio MP 8001
CategoryAll in One Printer
LanguageEnglish

Related product manuals