Bit Switches - 4
SM 121 D418
Fax Option
Type 9001
D418
G3 Switch 0E (SP No. 1-105-015)
No Function Comments
Set CNG send time interval
Some machines on the receiving side may not be able to automatically switch the
3-second CNG interval.
High order bit
3000-2250ms: 3000-50xNms
3000 – 50 x Nms 0F (3000 ms) ≤ N ≤ FF (2250
ms)
0-7
Low order bit
00-0E(3000-3700ms: 3000+50xNms
3000 – 50 x Nms 0F (3000 ms) ≤ N ≤ 0F (3700
ms)
G3 Switch 0F (SP No. 1-105-016)
No Function Comments
0
Alarm when an error occurred
in Phase C or later
0: Disabled
1: Enabled
If the customer wants to hear an alarm after each
error communication, change this bit to "1".
1
Alarm when the handset is
off-hook at the end of
communication
0: Disabled
1: Enabled
If the customer wants to hear an alarm if the
handset is off-hook at the end of fax
communication, change this bit to "1".
2-3 Not used Do not change the settings.
4
Sidaa manual calibration
setting
0: Off
1: On
1: manually calibrates for communication with a
line, whose current change occurs such as an
optical fiber line.
5-7 Not used Do not change the settings.