USING SERVICE PROGRAM MODES 20 February, 2001
5-18
5
Mode Number/Name Function/[Setting]
PM Alarm Mode
1 Interval Sets the base PM interval.
[1 ~ 255 / 60 / 1K copies/step]
The value stored in this SP is used when the value of
SP5-501-2 is “1”.
501*
2On/Off
Enables/disables the PM alarm for the total number of
prints, copies, and faxes.
[0 = No / 1 = Yes]
Memory All Clear801
Resets all software counters and returns all modes and
adjustments to their defaults settings (except for some
settings, such as SP5-811, SP5-907, SP5-916, and SP7-
003 – 5.1.8 Memory All Clear for a full list).
[0 = No / 1 = Yes]
After selecting “1”, press the Original Type key and the
! key at the same time to execute the clear. If the clear
is successful, the display shows “Action completed”. If
the clear fails, the display shows “Error!!!”.
This SP mode should be used only after replacing the
NVRAM or when the copier has malfunctioned due to
damaged NVRAM.
5.1.8 Memory All Clear
Scanner/Printer Free Run802
Starts a free run of both the scanner and the printer.
[0: = No / 1 = Yes]
After selecting “1”, press the OK key or ! key twice to
start the run. Press " to stop the free run.
Input Check803
Displays the signals being received from sensors and
switches.
Press # to exit the program.
5.1.3 Input Check
Output Check804
Turns on electrical components individually for test
purposes.
5.1.4 Output Check
Display Language Group807*
Selects the display language group.
[0 = Standard / 1 = Option 1 / 2 = Option 2]
The actual display language can be selected using User
Tools: [6. Language]
mm/inch Selection809*
Selects whether the display shows values in mm or
inches.
[North Am.: 0 = inch / 1 = mm]
[EU/Asia: 0 = mm / 1 = inch]

Table of Contents