20 February, 2001 USING SERVICE PROGRAM MODES
5-19
Service
Tables
5
Mode Number/Name Function/[Setting]
SC Code Reset810
Resets all level-A service call conditions, such as fusing
errors. (To reset SC 547, switch the machine off/on.)
[0 = No / 1 = Yes]
• After selecting “1”, press the Original Type key and the
' key (or OK key) at the same time to execute the
reset. If the reset is successful, the display shows
“Action completed.” If the reset fails, the display shows
“Error!!!”.
☛
4.1 Service Call Conditions
Serial Number Input811*
Used to input the machine serial number (normally done
at the factory). This is the serial number printed on SMC
reports.
☛
5.1.13 Serial Number Input
Service Telephone Number
1 Telephone Use this to input the telephone number of the service
representative. (The number is displayed when a service
call condition occurs.)
• To input a dash, press !.
• To delete the current telephone number, press %.
812*
2 Facsimile
Use this to input the fax number printed on user counter
reports.
• To input a dash, press !.
• To delete the current fax number, press %.
NVRAM Data Upload824
Uploads SP and UP mode data (except for some items
such as counters and the serial number) from the flash
memory on the BiCU board to a flash memory card.
[0 = No / 1 = Yes]
This SP can be used when a flash memory card has been
plugged into the machine’s card slot.
☛
5.1.11 NVRAM Data Upload/Download
NVRAM Data Download825
Downloads SP mode data from a flash memory card to
the flash memory on the BiCU board.
[0 = No / 1 = Yes]
This SP can be used when a flash memory card has been
plugged into the machine’s card slot.
☛
5.1.11 NVRAM Data Upload/Download
Program Upload826
Uploads the system program from the flash memory on
the BICU board to a flash memory card.
[0 = No / 1 = Yes]
This SP can be used when a flash memory card has been
plugged into the machine’s card slot.
☛
5.1.10 Program Upload/Download