USING SERVICE PROGRAM MODES 20 February, 2001
5-30
7
Mode Number/Name Function/[Setting]
Display – Developer Counter908*
Display the total number of prints made since the last
Developer Initialization (SP2-214).
Note that this counter does not double count, even for A3
and 11" x 17". Developments are counted up at paper
exit.
Display - ID Sensor Error Counter911*
Displays the total number of logged ID sensor errors.
For the error analysis procedure,
☛
5.1.14 ID Sensor
Error Analysis.
Reset - ID Sensor Error Counter912
Resets the ID sensor error counter.
[0 = No / 1 = Yes]
After selecting “1”, press the Original Type key and the
OK key (or ' key) at the same time to execute the reset.
If the reset is successful, the display shows “Action
completed.” If the reset fails, the display shows “Error!!!”.
Display - Timer Counter991*
Displays the total ON time for the machine.